Flameproof Manual Call Point
Flameproof Manual Call Point

Flameproof Manual Call Point

Price 2500 INR/ Piece

MOQ : 5 Pieces

Flameproof Manual Call Point Specification

  • Overheating Protection
  • YES
  • IP Rating
  • IP66
  • Efficiency
  • High
  • Operating Temperature
  • -20C to +60C
  • Feature
  • Manual Break Glass Operation, Resettable
  • Shape
  • Square
  • Humidity %
  • Up to 95% RH, Non-condensing
  • Connector Type
  • Cable Gland
  • Surface Finish
  • Powder Coated
  • Mounting Type
  • Wall Mounted
  • Insulation Material
  • Glass Epoxy
  • Product Type
  • Manual Call Point
  • Application
  • Fire Alarm System, Industrial Safety
  • Protection Level
  • Flameproof (Explosion Proof)
  • Frequency (MHz)
  • 50 Hz
  • Rated Voltage
  • 230 V AC
  • Energy Consumption
  • Negligible
  • Output Type
  • Switch/Contact Output
  • Color
  • Red
  • Dimension (L*W*H)
  • Approx. 120 x 120 x 85 mm
  • Weight
  • 800 g
  • Input Voltage
  • 230 V AC
  • Phase
  • Single Phase
  • Size
  • Standard
  • Connection Type
  • Terminal Block
  • No Of Poles
  • 1 Pole
  • Material
  • Die Cast Aluminium
  • Ingress Protection
  • Water & Dust Tight
  • Service Life
  • > 10 Years
  • Zone Classification
  • IIA, IIB (as per IS/IEC 60079-1)
  • Contact Rating
  • 6A @ 230 V AC
  • Reset Mechanism
  • Key Resettable
  • Glass Type
  • Toughened Break Glass
  • Number of Terminals
  • 2
  • Cable Entry
  • 2 x 3/4'' ET
 

Flameproof Manual Call Point Trade Information

  • Minimum Order Quantity
  • 5 Pieces
  • Supply Ability
  • 1000 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About Flameproof Manual Call Point



Discover the ultimate in industrial safety with our Flameproof Manual Call Point, designed for unassailable protection in hazardous environments. With a powder-coated die-cast aluminium body and toughened break glass, this device offers unmatched reliability. Its IP66 ingress protection ensures it remains water and dust-tight, while negligible energy consumption and a >10-year service life add enduring value. Take advantage of competitive pricing on this scarce, deal-worthy product-perfect for applications requiring robust, explosion-proof performance. Elevate your fire alarm system with this lustrous, high-efficiency solution.

Versatile Application in Industrial Safety

The Flameproof Manual Call Point is primarily used in fire alarm systems for industrial and hazardous areas classified as IIA and IIB. Its manual break glass operation offers immediate response, making it crucial for emergency environments. Beyond fire safety, it is also suited for facilities seeking explosion-proof measures. Commonly installed in manufacturing plants, refineries, and warehouses, this call point is engineered for sites requiring maximum safety and reliability under rigorous conditions.


Domestic Market Leadership & Secure Shipping

Serving the domestic market across India, we offer the Flameproof Manual Call Point with secure shipping and robust packaging to ensure safe delivery. Each unit is supplied with quality certifications, affirming adherence to IS/IEC 60079-1 standards. Our packaging guarantees the product arrives undamaged, ready for installation. By choosing this solution, customers receive the benefit of competitive offers, backed by reliable after-sales support, making us a trusted supplier throughout the country.


FAQ's of Flameproof Manual Call Point:


Q: How does the Flameproof Manual Call Point provide safety in hazardous areas?

A: This device offers explosion-proof protection, using a toughened break glass and robust die-cast aluminium housing. It operates reliably in zones classified as IIA, IIB, ensuring immediate manual activation during fire emergencies.

Q: What are the specific installation requirements for the Flameproof Manual Call Point?

A: Installation is designed for wall mounting using a standard terminal block connection, with cable entries (2 x 3/4 ET) accommodating industry-standard wiring for single-phase systems.

Q: When is it recommended to use this call point in industrial settings?

A: It should be installed in any environment where hazardous, flammable substances are present, such as petrochemical plants, paint factories, or storage facilities, to ensure rapid fire detection and response.

Q: Where can the Flameproof Manual Call Point be effectively utilized apart from fire alarms?

A: Besides fire alarm systems, it is ideal for industrial safety applications that require explosion-proof protection, such as emergency shutdown processes in highly sensitive zones.

Q: What benefit does the key resettable mechanism offer users?

A: The key resettable mechanism provides added security and convenience, allowing authorized personnel to easily restore the call point after activation, minimizing system downtime.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email



Back to top